Assembly instructions

The PCB must be removed from the optical mouse first. Then the VDD, GND, SCK and SDIO pins must be soldered to wires leading to the microcontroller and its internal 5V power supply.

Figure1
Figure 1. Soldered pins on the ADNS-2610

Insert the two M3 brass threaded inserts into the sensor holder by applying pressure. Attach the sensor to the sensor holder using 2 M3 screws.

Figure2
Figure 2 Optical sensor assembly

Then follow the instructions in Figure 3 to assemble the three Thorlabs components with the sensor holder.

Figure3
Figure 3. Optical sensor assembly

The lens must be glued to the PCB in the correct position, with the lens aligned with the optical flow sensor.

Figure4
Figure 4. ADNS-2610 glued with the lens

Attach the whole assembly on the rotary stage platform (e.g. at 0 or 90 degrees to the animal's anteroposterior axis).

Figure5
Figure 5. Optical sensor – platform assembly

Connect the pins on the PCB 5V, GND, and two digital pins as shown on the "electrical setup and configuration" page.